NOS 19

PCM1704UK & DSP built in
32bit / 768K support
32bit / 384K Asynchronous Transfer  XMOS U208 Chip
C
lass A PSUs and Class A analog amps design

                 

            

       
Summarize Use Manual Specs Custom Option Shipping Cost

Use Manual:

Power button:
Power ON/Off the DAC.

Setting button:
Select the phase of output signal  , pull off for the normal output, push into for invert output .

Selector button:
Select the input sources.   1: USB input. 2: HDMI . 3: C
oaxial  input. 4 :  Optical input. (Please note : The version without HDMI, select both 2 and 3 are the coaxial input.)

DSP-1 Jumpers setting


The product shipping before Oct. 12th. 2016

Jumpers Number

Setting

Functions describing

Jumper1  PLLEN

J1 (ON) ,J2(OFF) :PLL1 active
J1 (OFF) ,J2(ON) : PLL 2 active
J1 (OFF),J2(OFF) :    All PLL off
J1(ON), J2(ON)    :    All PLL off

PLL 1 setting for both NOS modes

Jumper2  ATT0

PLL 2 setting for  NOS mode 1 only

Jumper4  IPS0

J4 (ON) : NOS mode 2

J4 (OFF) : NOS mode 1

NOS modes selection

Jumper5  IPS1

J5 (ON) :Smoother

J5 (OFF) : Neutral

Sound flavor selection

Jumper6  DITH

J6 (ON) :Asynchronous mode2  active

J6 (OFF) :Asynchronous mode1 active

Asynchronous  mode selection


The product shipping in or after Oct. 12th. 2016

Jumpers Number

Setting

Functions describing

Jumper1  PLLEN

J1(ON), J2(ON)    :    PLL1 active
J1 (ON) ,J2(OFF) : PLL2 active
J1 (OFF) ,J2(ON) :    All PLL off
J1 (OFF),J2(OFF) :    All PLL off

PLL select for setting for all NOS modes

Jumper2  ATT0

Jumper3  ATT1

J3 (ON) :Smoother

J3 (OFF) : Neutral

Sound flavor selection

Jumper4  IPS0

J4 (ON),J5 (ON) : NOS mode 1
J4 (ON),J5 (OFF) : NOS mode 3
J4 (OFF),J5 (ON) : NOS mode 2
J4 (OFF),J5 (OFF) : NOS mode 1

NOS modes selection

Jumper5  IPS1

Jumper6  DITH

J6 (ON) :Asynchronous mode2  active

J6 (OFF) :Asynchronous mode1 active

Asynchronous  mode selection


Note:     ON mean the jumper push on.
              OFF mean the jumper pull off.
              Before witch the jumper ,for avoid the people body if had the static electric will damage the chips in the unit.


 